Industria eolikoko palen efizientzia aerodinamikoaren azterketa esperimentala baldintza ideal eta errealetan
dc.contributor.author | Zarketa Astigarraga, Ander | eus |
dc.contributor.author | Penalba Retes, Markel | eus |
dc.contributor.author | Martin Mayor, Alain | eus |
dc.contributor.author | Martinez Agirre, Manex | eus |
dc.date.accessioned | 2024-11-27T11:50:34Z | |
dc.date.available | 2024-11-27T11:50:34Z | |
dc.description.abstract | Energia berriztagarrien paradigmak erronka ugari dakartza berorrekin, epe laburrean erantzun beharrekoak bede-ren. Energia eolikoaren kasuan, ustiapena ohiko haize-parkeetatik itsasalde edota hiriguneetara mugitzean datza,inpaktu bisuala nahiz ingurumen kalteak murrizteko asmoz. Horrek haizearen fluxu baldintzak nabarmen aldatzeadakar; bereziki, turbulentzia eta ingurumen-eragileek sorturiko gainazal-zimurtasuna hartu behar da kontuan eta,hiriguneetako kasuan, aerosorgailuen eskala aldaketa.Haize-tunel bidezko entseguak burutuz, faktore horiekNACA0021 geometriadun pala baten efizientzia aerodinamikoan duten eragina aztertu da, baldintza idealetatikerrealetara igarotzean ematen den efizientzia galera ikusaraziz. Galera hori dela-eta, entsegu esperimentalak hariketa baldintza errealenetan egiteko beharra ondorioztatzen da. | eus |
dc.description.abstract | The paradigm of renewable energies brings a number of challenges to be solved in a short-term period. Inthe case of wind energy, it turns necessary to relocate onshore wind-farms in both offshore coastal regions andurban environments, so that visual and environmental impacts of current devices are reduced. This modifies theflow regime noticeably; indeed, turbulence and environmentally-induced roughness need to be accounted for, inaddition to the scale-effect in case of urban wind turbines. The effects of such factors on the aerodynamic efficiencyof a standard NACA0021 airfoil are tested via wind-tunnel measurements, showing the resultant decrease inaerodynamic efficiency when passing from ideal to real flow conditions. Such a decrease leads to concluding thataerodynamic tests should be undertaken with flow configurations that represent real operational conditions. | en |
dc.identifier.doi | https://dx.doi.org/10.26876/ikergazte.iv.03.10 | |
dc.identifier.other | production.44655 | |
dc.identifier.uri | https://gordailua.ueu.eus/handle/123456789/2469 | |
dc.relation.ispartof | IV. Ikergazte. Nazioarteko ikerketa euskaraz. Kongresuko artikulu bilduma. Ingeniaritza eta Arkitektura | |
dc.subject | energia eolikoa | eus |
dc.subject | aerodinamika esperimentala | eus |
dc.subject | efizientzia aerodinamikoa | eus |
dc.subject | turbulentzia | eus |
dc.subject | gainazal zi-murtasuna | eus |
dc.subject | wind energy | en |
dc.subject | esperimental aerodynamics | en |
dc.subject | aerodynamic efficiency | en |
dc.subject | turbulence | en |
dc.subject | surface roughness | en |
dc.subject.other | Ingeniaritza | eus |
dc.subject.other | Mekanika | eus |
dc.title | Industria eolikoko palen efizientzia aerodinamikoaren azterketa esperimentala baldintza ideal eta errealetan | eus |
dc.type | introduction | en |